Editing Modem Settings (FF240, FF440, or FF840)

Requires FaxFinder 3.0.4 or higher.

HTTP Request Line

PUT /ffws/v1/modem/MODEM HTTP/1.1 (where MODEM is a number from 1-24 depending on FaxFinder model and if using an Expansion Module.)

HTTP Response Status Codes

200 OK

Modem settings successfully changed.

400 Bad Request

The provided XML is not valid.

Example

PUT /ffws/v1/modem/1 HTTP/1.1 
content-type: application/xml 
authorization: Basic YWRtaW46YWRtaW4=
<?xml version=”1.0” encoding=”UTF-8”?> 
	<modem>
		<number>1</number>
		<fax_id>x40 Modem 1</fax_id>
		<country_code>United States(US)</country_code>
		<answer_on>2</answer_on>
		<max_extension_digits>4</max_extension_digits>
		<routing>Pots Line</routing>
		<routing_definition></routing_definition>
		<baud_rate>33600</baud_rate>
		<dial_prefix></dial_prefix>
		<init_string></init_string>
		<fax_direction></fax_direction>
		<error_correction>true</error_correction>
		<smart_dial>true</smart_dial>
		<tone_dial>true</tone_dial>
		<fax_debugging>false</fax_direction>
	</modem>
----------------------------------- 
HTTP/1.1 200 OK 
content-type: application/xml
<?xml version=”1.0” encoding=”UTF-8”?> 
<response>
	<message>Modified</message>
</response>