Viewing Modem, Channel, System, Printer, and Share Status

Requires FaxFinder 3.0.4 or higher.

HTTP Request Line

GET /ffws/v1/status HTTP/1.1

GET /ffws/v1/status/MODEM HTTP/1.1 (FF240, FF440, or FF840)

GET /ffws/v1/status/CHANNEL HTTP/1.1 (FF240-IP)

GET /ffws/v1/status/SYSTEM HTTP/1.1

GET /ffws/v1/status/PRINTER HTTP/1.1

GET /ffws/v1/status/SHARE HTTP/1.1

HTTP Response Status Codes

200 OK

Shows status information.

400 Bad Request

The provided XML is not valid.

FF240, FF440, or FF840 Example

GET /ffws/v1/status HTTP/1.1 
content-type: application/xml 
authorization: Basic YWRtaW46YWRtaW4= 
----------------------------------- 
HTTP/1.1 200 OK 
content-type: application/xml
<?xml version=”1.0” encoding=”UTF-8”?> 
<response>
  <message>Success</message>
  <status>
	   <modem> 
			<number_inbound></number_inbound>
			<number_outbound></number_outbound>
			<number_idle></number_idle>
		</modem>
		<system>
			<uptime></uptime>
			<current_time></current_time>
			<time_server></time_server>
		</system>
		<printer>
			<name></name>
			<status></status>
			<jobs></jobs>
		</printer>
		<network_share>
			 <share></share>
			 <status></status>
		</network_share>
  </status>
</response>

FF240-IP Example

GET /ffws/v1/status HTTP/1.1 
content-type: application/xml 
authorization: Basic YWRtaW46YWRtaW4= 
----------------------------------- 
HTTP/1.1 200 OK 
content-type: application/xml
<?xml version=”1.0” encoding=”UTF-8”?> 
<response>
  <message>Success</message>
  <status>
	   	<channel>
			<number_inbound></number_inbound>
			<number_outbound></number_outbound>
			<number_idle></number_idle>
		</channel>
		<system>
			<uptime></uptime>
			<current_time></current_time>
			<time_server></time_server>
		</system>
		<printer>
			<name></name>
			<status></status>
			<jobs></jobs>
		</printer>
		<network_share>
			 <share></share>
			 <status></status>
		</network_share>
  </status>
</response>