Sending Data from one mDot to Multiple Conduits

Home Forums mDot/xDot Sending Data from one mDot to Multiple Conduits

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #19564
    Katie Hughes
    Participant

    Hello, We are trying to send the same data (Broadcast) from mDot to two Conduits. The Conduits share the same configuration including Network Name, Paraphrase and Frequency Sub Band. I am using OTA join mode and class A operation. The problem I am facing is that data is only sent to one Conduit at a time if both the conduit are On. How to broadcast data to more than one conduit? Help needed!
    Thank you.

    #19565
    Jason Reiss
    Keymaster

    The mDot will only join one Conduit in OTA.
    The session information is not shared between Conduits.

    ABP activation could be used to receive the broadcast from mDots.

    Perhaps an application on Conduit can communicate over ethernet?

    #19580
    Katie Hughes
    Participant

    Hello, Thank you for your reply! We switched the join mode to manual mode and On both conduits we created a node with same Network Address, network_session_key and data_session_key. It worked. But now every time we poweroff the mDot, we are manually having to create a new node on both the Conduits. Bummer! But Thanks for the quick reply!!!

    #19582
    Jason Reiss
    Keymaster

    The counter value can be saved on mdot with at+ss before power off and restored with at+rs.

    This will keep it in sync.

Viewing 4 posts - 1 through 4 (of 4 total)